 MADSEN Zodiac 901 - Middle ear analyzer, tympanometer 

The MADSEN Zodiac 901 middle ear analyzer and tympanometer offers the best of both worlds: fast, automatic tympanometry and reflex threshold screening, where speed is paramount, coupled with the accuracy and versatility of a clinical instrument.

Overview 
Overview 

Fully automatic screening
Zodiac 901 enables you to seal the probe quickly, run fast automatic tymp and reflex measurements, print out the results (or transfer them to your PC), and rely on their accuracy.

In Auto Mode, you can choose between preset test sequences or program the instrument with your own test routines complete with pauses, printout and data transfer. By providing you with automatic test sequences, the Zodiac takes the routine, repetitive work out of immittance testing. It also makes it possible for multiple operators to program their own default parameters for tympanometry and reflex threshold testing.

Zodiac 901 offers you the best of middle ear analysis
In addition to fast, automatic tympanometry and reflex screening,  Zodiac 901 is ideal for the clinician who wants a sensitive and accurate instrument with complete immittance testing capabilities and full manual control over all test parameters.

Connectivity
You can transfer all immittance data to your PC, and save them in NOAH in the same client session as your other audiologic data. Zodiac 901 can also be customized by means of our ZODICON software into your personal middle-ear analyzer entering your own preferred default settings for example, or adding your logo and address to the internal printout.

Zodiac can print out on the optional built-in printer or to an external printer.


Features 
Features at a glance 
  • Large, clear display that can be read in any light
  • Quiet built-in thermal printer option
  • Audiometer function for air conduction thresholds (8 frequencies, 0-120 dB HL)
  • 4 preset and 4 user-programmable auto test sequences
  • Flexible probe solution can be hand-held or mounted on a shoulder harness or headset
  • Optional Zodi-Link PC software for data transfer to NOAH
  • Built-in Ear Simulator and precision 2cc cavity located in one side of the instrument
  • Analog meter display option
  • On-screen marker for reflex decay, latency and amplitude measurement
  • Screening tests:
    • Automatic tympanometry          
    • Automatic acoustic reflex (Ipsi/Contra)
    • Automatic reflex threshold (Ipsi/Contra)
    • Pure tone threshold (air conduction)
  • Clinical tests:

o    Manual tympanometry

o    Manual acoustic reflex (Ipsi/Contra)

o    Reflex decay (Ipsi/Contra)

o    Pure tone threshold (air conduction)

o    Eustachian Tube Function

o    Acoustic Reflex Latency

o    Gelle's test